A ribbed square duct (, ) subjected to sand ingestion is studied using large-eddy simulations (LES). Particle sizes of , , and with nondimensional response times (normalized by friction velocity and hydraulic diameter) of 0.06875, 1.71875, and 6.875, respectively are considered. The calculations are performed for a nominal bulk Reynolds number of 20,000 under fully-developed conditions. Distributions of impingement density, impingement velocities and angles, together with fractional energy transfer are presented for each surface. It is found that about 40% of the total number of particles are concentrated in the vicinity (within 0.05 ) of the duct surfaces, compared to 25–30% of the 50 and particles. The particles are more sensitive to the primary and secondary flow velocities than the larger particles. While the particles exhibit high energy transfer to the surface near the rib side-wall junction and immediately upstream of the rib, the larger particles exhibit more uniform distributions. The largest fraction of incoming particulate energy is transferred to the front face of the rib and is between one to two orders of magnitude larger than the other surfaces. As particle size increases, substantial particle energy is also transferred to the back face of the rib by particles bouncing off the front face and carrying enough momentum to impinge on the back face of the preceding rib.
Skip Nav Destination
Article navigation
October 2007
Research Papers
Transport of Particulates in an Internal Cooling Ribbed Duct
Anant Shah,
Anant Shah
High Performance Computational Fluids, Thermal Sciences and Engineering Lab, Mechanical Engineering Department,
Virginia Polytechnic Institute and State University
, Blacksburg, VA 24061
Search for other works by this author on:
Danesh K. Tafti
Danesh K. Tafti
High Performance Computational Fluids, Thermal Sciences and Engineering Lab, Mechanical Engineering Department,
Virginia Polytechnic Institute and State University
, Blacksburg, VA 24061
Search for other works by this author on:
Anant Shah
High Performance Computational Fluids, Thermal Sciences and Engineering Lab, Mechanical Engineering Department,
Virginia Polytechnic Institute and State University
, Blacksburg, VA 24061
Danesh K. Tafti
High Performance Computational Fluids, Thermal Sciences and Engineering Lab, Mechanical Engineering Department,
Virginia Polytechnic Institute and State University
, Blacksburg, VA 24061J. Turbomach. Oct 2007, 129(4): 816-825 (10 pages)
Published Online: August 4, 2006
Article history
Received:
August 2, 2006
Revised:
August 4, 2006
Citation
Shah, A., and Tafti, D. K. (August 4, 2006). "Transport of Particulates in an Internal Cooling Ribbed Duct." ASME. J. Turbomach. October 2007; 129(4): 816–825. https://doi.org/10.1115/1.2720509
Download citation file:
Get Email Alerts
Related Articles
Large Eddy Simulation of Flow and Heat Transfer in the 180 ‐ Deg Bend Region of a Stationary Gas Turbine Blade Ribbed Internal Cooling Duct
J. Turbomach (October,2006)
Fluid Flow and Heat Transfer in Rotating Curved Duct at High Rotation and Density Ratios
J. Turbomach (October,2005)
Heat Transfer on Internal Surfaces of a Duct Subjected to Impingement of a Jet Array with Varying Jet Hole-Size and Spacing
J. Turbomach (January,2006)
Investigation of Cooling Effectiveness of Gas Turbine Inlet Fogging Location Relative to the Silencer
J. Eng. Gas Turbines Power (February,2012)
Related Proceedings Papers
Related Chapters
Inside the Building
Geothermal Heat Pump and Heat Engine Systems: Theory and Practice
The Cause of Most Field Problems
Heat Exchanger Engineering Techniques
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential