A comprehensive set of generic experiments is conducted to investigate the interaction of film cooling rows. Five different film cooling configurations are considered on a large-scale basis each consisting of two rows of film cooling holes in staggered arrangement. The hole pitch to diameter ratio within each row is kept constant at The spacing between the rows is either 20, or 30. Fan-shaped holes or simple cylindrical holes with an inclination angle of 30 deg and a hole length of 6-hole diameters are used. With a hot gas Mach number of an engine like density ratio of and a freestream turbulence intensity of are established. Operating conditions are varied in terms of blowing ratio for the upstream and, independently, the downstream row in the range The results illustrate the importance of considering ejection into an already film-cooled boundary layer. Adiabatic film cooling effectiveness and heat transfer coefficients are significantly increased. The decay of effectiveness with streamwise distance is much less pronounced downstream of the second row primarily due to pre-cooling of the boundary layer by the first row of holes. Additionally, a comparison of measured effectiveness data with predictions according to the widely used superposition model of Sellers is given for two rows of fanshaped holes.
Skip Nav Destination
Article navigation
April 2004
Technical Papers
Interaction of Film Cooling Rows: Effects of Hole Geometry and Row Spacing on the Cooling Performance Downstream of the Second Row of Holes
Christian Saumweber
Christian Saumweber
Lehrstuhl und Institut fu¨r Thermische Stro¨mungsmaschinen, Universitat Karlsruhe (T.H.), Kaiserstr. 12, Karlsruhe 76128, Germany
Search for other works by this author on:
Christian Saumweber
Lehrstuhl und Institut fu¨r Thermische Stro¨mungsmaschinen, Universitat Karlsruhe (T.H.), Kaiserstr. 12, Karlsruhe 76128, Germany
Contributed by the International Gas Turbine Institute and presented at the International Gas Turbine and Aeroengine Congress and Exhibition, Atlanta, GA, June 16–19, 2003. Manuscript received by the IGTI December 2002; final revision March 2003. Paper No. 2003-GT-38195. Review Chair: H. R. Simmons.
J. Turbomach. Apr 2004, 126(2): 237-246 (10 pages)
Published Online: June 15, 2004
Article history
Received:
December 1, 2002
Revised:
March 1, 2003
Online:
June 15, 2004
Citation
Saumweber, C. (June 15, 2004). "Interaction of Film Cooling Rows: Effects of Hole Geometry and Row Spacing on the Cooling Performance Downstream of the Second Row of Holes ." ASME. J. Turbomach. April 2004; 126(2): 237–246. https://doi.org/10.1115/1.1731395
Download citation file:
Get Email Alerts
Related Articles
A Converging Slot-Hole Film-Cooling Geometry—Part 2: Transonic Nozzle Guide Vane Heat Transfer and Loss
J. Turbomach (July,2002)
Heat Transfer and Film Cooling of Blade Tips and Endwalls
J. Turbomach (July,2012)
Film Cooling Measurements for Novel Hole Configurations
J. Heat Transfer (August,2006)
High-Resolution Measurements of Local Effectiveness From Discrete Hole Film Cooling
J. Turbomach (October,2001)
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Applications
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential