The long-term success of a total knee replacement depends on the wear performance of a polyethylene bearing that separates a metal femoral component from a metal tibial tray. Although fixed bearing designs secure the polyethylene bearing to the tibial tray, mobile bearing knees allow the polyethylene to move relative to the tibial tray. This study has evaluated the wear performance of an intended articulation on the inferior surface of the LCS®-Rotating Platform mobile bearing by conducting clinically relevant tribological testing and comparing results to retrieved knee bearings. A retrieval analysis leads to the conclusion that third-body particles in the contact produce curvilinear scratches longer than the expected rotation of the knee on both the polyethylene bearing and the CoCr tibial tray. Tribological testing shows that polymethylmethacrylate (PMMA) bone cement particles produce worn surfaces most similar to retrievals. Porous-coating beads and bone debris also have the ability to damage both surfaces. Worn polyethylene surfaces from pin-on-flat tests show scratches longer than the excursion length, and “skipping marks”—pits spaced at smaller rotation intervals along a scratch—as observed in retrievals. These wear features suggest that a ratcheting mechanism, which moves the third-body particles further along the scratch with each cycle, may be responsible for the observed wear.

1.
Williams
,
J. A.
, 1994,
Engineering Tribology
,
Oxford University Press
,
London, UK
, pp.
258
260
.
2.
Kennedy
,
F. E.
,
Currier
,
B. H.
,
Van Citters
,
D. W.
,
Currier
,
J. H.
,
Collier
,
J. P.
, and
Mayor
,
M. B.
, 2003, “
Oxidation of Ultra-High Molecular Weight Polyethylene and its Influence on Contact Fatigue and Pitting of Knee Bearings
,”
Tribol. Trans.
1040-2004,
46
, pp.
111
118
.
3.
Ajayi
,
O. O.
,
Shi
,
B.
,
Soppet
,
M. J.
,
Erdemir
,
A.
,
Liang
,
H.
, and
Fenske
,
G. R.
, 2003, “
Engineered Surfaces for Artificial Joint Application
,” Proceedings of 2003 STLE/ASME Joint International Tribology Conference, Jacksonville, FL.
4.
Jordan
,
L. R.
, and
Olivio
,
J. L.
, 2002, “
Aseptic Loosening in the LCS Total Knee Arthroplasty
,”
LCS: Mobile Bearing Knee Arthroplasty
,
K. J.
Hamelynck
, ed.,
Springer
,
New York
, pp.
253
259
.
5.
Ingram
,
J. H.
,
Stone
,
M.
,
Fisher
,
J.
, and
Ingram
,
E.
, 2004, “
The Influence of Molecular Weight, Crosslinking and Counterface Roughness on TNF-Alpha Production by Macrophages in Response to Ultra High Molecular Weight Polyethylene Particles
,”
Biomaterials
0142-9612,
25
(
17
), pp.
3511
3522
.
6.
Collier
,
J. P.
,
Sperling
,
D. K.
,
Currier
,
J. H.
,
Sutula
,
L. C.
,
Saum
,
K. A.
, and
Mayor
,
M. B.
, 1996, “
Impact of Gamma Sterilization on Clinical Performance of Polyethylene in the Knee
,”
J. Arthroplasty
0883-5403,
11
(
4
), pp.
377
389
.
7.
Williams
,
I. R.
,
Mayor
,
M. B.
, and
Collier
,
J. P.
, 1998, “
The Impact of Sterilization Method on Wear in Knee Arthroplasty
,”
Clin. Orthop. Relat. Res.
0009-921X,
356
, pp.
170
180
.
8.
Callaghan
,
J. J.
,
Squire
,
M. W.
,
Goetz
,
D. D.
,
Sullivan
,
P. M.
, and
Johnston
,
R. C.
, 2000, “
Cemented Rotating-Platform Total Knee Replacement: A Nine to Twelve-Year Follow-Up Study
,”
J. Bone Jt. Surg., Am. Vol.
0021-9355,
82-A
(
5
), pp.
705
711
.
9.
Currier
,
B. H.
,
Currier
,
J. H.
,
Collier
,
J. P.
, and
Mayor
,
M. B.
, 2000, “
Effect of Fabrication Method and Resin Type on Performance of Tibial Bearings
,”
J. Biomed. Mater. Res.
0021-9304,
53
, pp.
143
151
.
10.
Currier
,
B. H.
,
Currier
,
J. H.
,
Collier
,
J. P.
,
Mayor
,
M. B.
, and
Scott
,
R. D.
, 1997, “
Shelf Life and In Vivo Duration
,”
Clin. Orthop. Relat. Res.
0009-921X,
342
, pp.
111
122
.
11.
Cuckler
,
J. M.
,
Lemons
,
J.
,
Tamarapalli
,
J. R.
, and
Beck
,
P.
, 2003, “
Polyethylene Damage on the Nonarticular Surface of Modular Total Knee Prostheses
,”
Clin. Orthop. Relat. Res.
0009-921X,
410
, pp.
248
253
.
12.
Conditt
,
M. A.
,
Ismaily
,
S. K.
,
Alexander
,
J. W.
, and
Noble
,
P. C.
, 2004, “
Backside Wear of Modular Ultra-High Molecular Weight Polyethylene Tibial Inserts
,”
J. Bone Jt. Surg., Am. Vol.
0021-9355,
86-A
(
5
), pp.
1031
1037
.
13.
Goodfellow
,
J. W.
, and
O’Connor
,
J.
, 2002, “
The Mechanics of Knee and Prosthesis Design
,” in
LCS Mobile Bearing Knee Arthroplasty: A 25Years Worldwide Review
,
K. J.
Hamelynck
, ed.,
Springer
,
New York
, pp.
3
15
.
14.
Jones
,
R. D.
, 2002, “
The Historical Perspective of Mobile-Bearing Knee Implants
,”
LCS: Mobile Bearing Knee Arthroplasty
,
K. J.
Hamelynck
, ed.,
Springer
,
New York
, pp.
17
18
.
15.
Atwood
,
S. A.
, 2005, “
Backside Wear Evaluation of LCS Rotating Platform Knee Replacements
,” MS thesis, Thayer School of Engineering, Dartmouth College, Hanover, NH.
16.
Hood
,
R. W.
,
Wright
,
T. M.
, and
Burstein
,
A. H.
, 1983, “
Retrieval Analysis of Total Knee Prostheses: A Method and Its Application to 48 Total Condylar Prostheses
,”
J. Biomed. Mater. Res.
0021-9304,
17
, p.
829
842
.
17.
Banks
,
S. A.
,
Markovich
,
G. D.
, and
Hodge
,
W. A.
, 1997, “
In Vivo Kinematics of Cruciate-Retaining and—Substituting Knee Arthroplasties
,”
Kangogaku Zasshi
0386-9830,
12
(
3
), pp.
297
304
.
18.
Kayaba
,
T.
,
Kato
,
K.
, and
Hokkirigawa
,
K.
, 1983, “
Theoretical Analysis of the Plastic Yielding of a Hard Asperity Sliding on a Soft Flat Surface
,”
Wear
0043-1648,
87
, pp.
151
161
.
19.
Rozeanu
,
L.
, and
Kennedy
,
F. E.
, 1999, “
Surface and Near-Surface Interactions Affecting Friction and Wear
,”
Lubrication at the Frontier
,
D.
Dowson
,
M.
Priest
,
C. M.
Taylor
,
P.
Ehret
,
T. H. C.
Childs
,
G.
Dalmaz
,
Y.
Berthier
,
L.
Flamand
,
J. M.
Georges
, and
A. A.
Lubrecht
, eds.,
Elsevier
,
Amsterdam
, pp.
665
672
.
20.
Pruitt
,
L. A.
, 2005, “
Deformation, Yielding, Fracture and Fatigue Behavior of Conventional and Highly Cross-Linked Ultra High Molecular Weight Polyethylene
,”
Biomaterials
0142-9612,
26
, pp.
905
915
.
21.
Ho
,
E.
, and
Marcolongo
,
M.
, 2005, “
Effect of Coupling Agents on the Local Mechanical Properties of Bioactive Dental Composites by the Nano-Indentation Technique
,”
Dent. Mater.
0109-5641,
21
(
7
), pp.
656
664
.
22.
Hengsberger
,
S.
,
Kulik
,
A.
, and
Zysset
,
P.
, 2001, “
A Combined Atomic Force Microscopy and Nanoindentation Technique to Investigate the Elastic Properties of Bone Structural Units
,”
Eur. Cells Mater
1473-2262,
1
, pp.
12
17
.
You do not currently have access to this content.