Skip Nav Destination
Issues
September 2007
ISSN 1932-6181
EISSN 1932-619X
In this Issue
Research Papers
In Vitro Quantification of Guidewire Flow-Obstruction Effect in Model Coronary Stenoses for Interventional Diagnostic Procedure
J. Med. Devices. September 2007, 1(3): 185–196.
doi: https://doi.org/10.1115/1.2776336
Topics:
Flow (Dynamics)
,
Pressure
,
Pressure drop
,
Pulsatile flow
,
Hemodynamics
,
Physiology
Device for Measurement of Human Tissue Properties In Vivo
J. Med. Devices. September 2007, 1(3): 197–205.
doi: https://doi.org/10.1115/1.2778703
Topics:
Biological tissues
,
Haptics
,
Muscle
,
Phantoms
,
Calibration
Miniaturized Cutting Tool With Triaxial Force Sensing Capabilities for Minimally Invasive Surgery
Pietro Valdastri, Keith Houston, Arianna Menciassi, Paolo Dario, Arne Sieber, Masaru Yanagihara, Masakatsu Fujie
J. Med. Devices. September 2007, 1(3): 206–211.
doi: https://doi.org/10.1115/1.2778700
Topics:
Calibration
,
Cutting
,
Cutting tools
,
Design
,
Force sensors
,
Manufacturing
,
Muscle
,
Robotics
,
Sensors
,
Signals
Synthetic Lumbar Intervertebral Disk for Medical Education
J. Med. Devices. September 2007, 1(3): 212–216.
doi: https://doi.org/10.1115/1.2778701
Topics:
Biomedicine
,
Design
,
Disks
,
Education
,
Engineering prototypes
,
Intervertebral discs
,
Surgery
,
Orthopedics
,
Feedback
Graphical Rendering of Localized Lumps for MIS Applications
J. Med. Devices. September 2007, 1(3): 217–224.
doi: https://doi.org/10.1115/1.2779260
Topics:
Algorithms
,
Biological tissues
,
Dimensions
,
Rendering
,
Sensors
,
Surgery
,
Tactile sensors
,
Design
Design Innovation Paper
Design of a Calibration Phantom for Measuring the Temporal Resolution of a Tomographic Imaging Device
J. Med. Devices. September 2007, 1(3): 225–232.
doi: https://doi.org/10.1115/1.2785189
Topics:
Calibration
,
Design
,
Disks
,
Engines
,
Gears
,
Imaging
,
Manufacturing
,
Motors
,
Phantoms
,
Planetary gears
Technical Brief
Lithography Technique for Topographical Micropatterning of Collagen-Glycosaminoglycan Membranes for Tissue Engineering Applications
J. Med. Devices. September 2007, 1(3): 233–237.
doi: https://doi.org/10.1115/1.2775937
Topics:
Membranes
,
Tissue engineering
,
Biomaterials
,
Lithography
,
Flow (Dynamics)
,
Endothelial cells
,
Pressure
Email alerts
RSS Feeds
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)