This project aims to investigate the performance of edge-to-edge mitral valve repair (MVR) within reanimated swine hearts. Direct imaging and hemodynamic data of the mitral valve during normal cardiac function (Normal), after an induced prolapse (Prolapse), and post surgical repair (E2E) was obtained. Isolated swine hearts were reanimated using a clear Krebs–Henseleit buffer. Mitral prolapse, and regurgitation, in the P2 region was induced by cutting chordae tendinae of the posterior leaflet. An edge-to-edge MVR procedure was performed, suturing the prolapsed P2 region to the A2 region of the anterior leaflet. The mitral valve was imaged using endoscopic cameras in the left atrium and ventricle allowing verification of stitch placement and leaflet coaptation. Analysis of the endoscopic images provided measures of annulus area, orifice area, and regurgitant area. Echocardiography, the standard clinical imaging modality, was used to determine the hemodynamic performance of the valve. Additionally, ECG and left chamber pressures were recorded at a sample rate of 5 kHz. Prolapse of the P2 region was consistently created, and edge-to-edge repair of the mitral leaflet showed full leaflet coaptation. The annulus area of the valve was tracked throughout the procedure and did not show significant variation. The orifice area, defined as the area of the annulus that does not contain leaflets, normalized to the corresponding annulus area for Normal, Prolapse and E2E were: , and , . The regurgitant area, normalized to the corresponding annulus area, increased from for Normal to for the Prolapse and then decreased to for the E2E group. The regurgitant fraction, normalized against the maximum observed, for Normal, Prolapse and E2E was , and , . Over the course of the experiment the left ventricular (LV) systolic pressure and negative dP/dt reduced from 95 to 54 mm Hg and 743 to 402 mm Hg/s, respectively. Our results show that orifice area was significantly smaller after MVR when compared to Normal and Prolapse periods. There was no significant change in regurgitant area and regurgitant fraction from the Normal to repaired valve as compared to a significant increase in regurgitant area and regurgitant fraction during Prolapse. Low gradients were observed for all three groups, with no indications for symptomatic stenosis. The reduction of LV function was caused by global ischemia and the progressive onset of edema. In this acute assessment of edge-to-edge repair of P2 prolapse, repair does not affect annulus area, decreases orifice area, and successfully eliminates regurgitant area with no evidence of mitral stenosis.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Visualization and Hemo-Dynamic Evaluation of Edge-to-Edge Mitral Valve Repair Within Reanimated Swine Hearts
J. Med. Devices. Jun 2009, 3(2): 027545 (1 pages)
Published Online: July 24, 2009
Article history
Published:
July 24, 2009
Citation
Bateman, M. G., Quill, J. L., St. Louis, J., and Iaizzo, P. A. (July 24, 2009). "Visualization and Hemo-Dynamic Evaluation of Edge-to-Edge Mitral Valve Repair Within Reanimated Swine Hearts." ASME. J. Med. Devices. June 2009; 3(2): 027545. https://doi.org/10.1115/1.3136430
Download citation file:
766
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Integrating Physicians, Researchers and Engineers— 60 Years of Medical Device Innovation at Mayo Clinic
J. Med. Devices (June,2008)
Novel Transaortic Double Barrel Ventricular Cannula
J. Med. Devices (June,2009)
The Evolution of the External Left Ventricular Assist Device
J. Med. Devices (June,2010)
Design Optimization of Single-Port Minimally Invasive Intervention Devices
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Introduction
Modified Detrended Fluctuation Analysis (mDFA)
Micromachined 1-3 Composite Single Element Transducers
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Computer-Aided Screening Program Management in Audiology and Cardiology
International Conference on Measurement and Control Engineering 2nd (ICMCE 2011)