While the function of central and peripheral nervous system decreases (caused by aging, vestibular deficiency or stroke), maintaining of body stability become hard. Studies indicate that movement coordination of axial segments (head, thorax, and pelvis) in a dynamic state such as walking disrupted in these pathologic conditions. In recent years goniometry and cinematography have been widely used to measure active or passive range of motion (ROM) in asymptomatic adults. The aim of this investigation is to design and implement a new method by evidence based approach for estimating the level of impairment in segment stability and improvement after treatment by measuring quality or quantity of movement among axial segments. Ultrasound based coordinate measuring system (CMS) can continuously measure motion in three dimensions during the course of time in a dynamic condition. The measuring procedure is based on the travel time measurement of ultrasonic pulses that are emitted by miniature transmitters (markers) to three microphones built into the compact device. Our system consist electronic, mechanic and software sections. Electronic board include: 40 KHz pulse oscillator, PRF pulse generator, sensor drivers, high voltage analog switches, 60 dB Amplifier, signal detector and CPU. Transmitter sensors which have been mounted on body send ultrasonic burst signals periodically and other 3 sensors which arranged on a T-shape Mechanical base receive the 3 dimensional coordinate of these transmitters. After sending 3D coordination data to PC via serial port, a complex and elaborative Visual Basic software calculate the angular dispersion, angular rate acceleration for each also calculate the stabilization parameters among segments such as Al (anchoring index) and cross-correlating between head and trunk coordinates.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Design of Ultrasonic Motion Analysis System for Estimating Segment's Stabilization During Dynamic Condition
N. Hemmati
N. Hemmati
IEEE Member, Research Center for Science and Technology in Medicine
, Tehran, Iran
Search for other works by this author on:
N. Hemmati
IEEE Member, Research Center for Science and Technology in Medicine
, Tehran, IranJ. Med. Devices. Jun 2009, 3(2): 027537 (1 pages)
Published Online: July 9, 2009
Article history
Published:
July 9, 2009
Citation
Hemmati, N. (July 9, 2009). "Design of Ultrasonic Motion Analysis System for Estimating Segment's Stabilization During Dynamic Condition." ASME. J. Med. Devices. June 2009; 3(2): 027537. https://doi.org/10.1115/1.3147500
Download citation file:
594
Views
Get Email Alerts
Cited By
Related Articles
Detection of Self-Stimulatory Behaviors of Children with Autism Using Wearable and Environmental Sensors
J. Med. Devices (June,2009)
Separating Aortic Stenosis From Nornal Heart Decision Spaces Using a Quadratic Model
J. Med. Devices (June,2009)
A Mobile Gait Monitoring System for Abnormal Gait Diagnosis and Rehabilitation: A Pilot Study for Parkinson Disease Patients
J Biomech Eng (April,2011)
Wireless Recharging of Implanted Batteries via Ultrasound
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Experimental Investigation of Ventilated Supercavitation Under Unsteady Conditions
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Generators, Motors and Switch Gears
Handbook for Cogeneration and Combined Cycle Power Plants, Second Edition
The Research on the DC Speed-Adjusting System Based on DSP
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3