Abdominal aortic aneurysms (AAA), which claim the lives of 15,000 Americans annually, occur when the aortic walls are weakened to the point of bulging or rupture. Besides aorta replacements, AAA is commonly treated with an endovascular aortic repair procedure that reinforces the aorta by inserting a stent via a leg artery. While this procedure is effective, failure of the stent may increase the pressure of the AAA sac and cause the aorta wall to rupture. Therefore, monitoring of the pressure in the AAA sac is critical for post surgery assessment. We present the design and fabrication of a wireless passive pressure sensor for measuring the pressure of an AAA sac after stent placement. The sensor is made of a hermetically sealed chamber with two opposite membranes. A magnetically soft film is attached on one of the membranes, and a permanent magnetic film is placed on the other. As the membranes deflect due to changes in sac pressure, the separation distance between the magnetic elements changes. This in turn varies the magnetic harmonic fields of the magnetically soft film, allowing remote pressure monitoring with the use of a magnetic coil. Compared to Endosure, a wireless passive sensor developed by CardioMems that operates by remotely measuring the resonant frequency change of a capacitive-inductive circuit, the proposed device is thinner and can be miniaturized to a long and thin strip. Its signal is also not reduced by the electrically dense body since it is interrogated through magnetic fields.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
A Wireless, Passive Sensor for Monitoring the Pressure of an Abdominal Aortic Aneurysm Sac
Brandon D. Pereles,
Brandon D. Pereles
Department of Biomedical Engineering,
Michigan Technological University
, 1400 Townsend Drive, Houghton, MI 49931, USA
Search for other works by this author on:
Keat Ghee Ong
Keat Ghee Ong
Department of Biomedical Engineering,
Michigan Technological University
, 1400 Townsend Drive, Houghton, MI 49931, USA
Search for other works by this author on:
Brandon D. Pereles
Department of Biomedical Engineering,
Michigan Technological University
, 1400 Townsend Drive, Houghton, MI 49931, USA
Keat Ghee Ong
Department of Biomedical Engineering,
Michigan Technological University
, 1400 Townsend Drive, Houghton, MI 49931, USAJ. Med. Devices. Jun 2008, 2(2): 027557 (1 pages)
Published Online: June 25, 2008
Article history
Published:
June 25, 2008
Citation
Pereles, B. D., and Ong, K. G. (June 25, 2008). "A Wireless, Passive Sensor for Monitoring the Pressure of an Abdominal Aortic Aneurysm Sac." ASME. J. Med. Devices. June 2008; 2(2): 027557. https://doi.org/10.1115/1.2936117
Download citation file:
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Real-Time, In Vivo Measurement of Contact Pressures at a Knee Arthroplasty
J. Med. Devices (June,2009)
Intra-Operative Pulse Oximetry
J. Med. Devices (June,2009)
Design of a Novel Experimental Setup for the Assessment of the Fossa Ovalis Within Large Mammalian Hearts: Investigating Tissue Properties and Clinical Devices Used for Transseptal Access
J. Med. Devices (June,2011)
3D CAD Based Conceptual Design of a Novel Aortic Valve Stent
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Conclusions and future perspectives
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
Section VIII: Division 2–Alternative Rules
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 2, Sixth Edition