This paper reports a miniaturized triaxial force sensorized cutting tool for minimally invasive robotic surgery. This device exploits a silicon-based microelectromechanical system triaxial force sensor that acts as the core component of the system. The outer diameter of the proposed device is less than 3mm, thus enabling the insertion through a 9 French catheter guide. Characterization tests are performed for both normal and tangential loadings. A linear transformation relating the sensor output to the external applied force is introduced in order to have a triaxial force output in real time. Normal force resolution is 8.2bits over a force range between 0N and 30N, while tangential resolution is 7 bits over a range of 5N. Force signals with frequencies up to 250Hz can successfully be detected, enabling haptic feedback and tissue mechanical properties investigation. Preliminary ex vivo muscular tissue cutting experiments are introduced and discussed in order to evaluate the device overall performances.

1.
Rebello
,
K.
, 2004, “
Applications of MEMS in Surgery
,”
Proc. IEEE
0018-9219,
92
(
1
), pp.
43
55
.
2.
Dario
,
P.
,
Hannaford
,
B.
, and
Menciassi
,
A.
, 2003, “
Smart Surgical Tools and Augmenting Devices
,”
IEEE Trans. Rob. Autom.
1042-296X,
19
(
5
), pp.
782
792
.
3.
Strandman
,
C.
,
Smith
,
L.
,
Tenerez
,
L.
, and
Hök
,
B.
, 1997, “
A Production Process of Silicon Sensor Elements for a Fibre-Optic Pressure Sensor
,”
Sens. Actuators, A
0924-4247,
63
(
1
), pp.
69
74
.
4.
Verimetra, Inc., Pittsburgh, PA, URL http://www.verimetra.comhttp://www.verimetra.com
5.
Millar Instruments, Inc., Houston, TX, USA. URL http://www.millarinstruments. comhttp://www.millarinstruments. com
6.
Ito
,
M.
,
Yamamoto
,
E.
,
Hashimoto
,
S.
,
Komazaki
,
I.
,
Miyajima
,
H.
,
Shinohara
,
S.
, and
Yanagisawa
,
K.
, 1995, “
Compound-Cavity Tactile Sensor Using Surface-Emitting Laser for Endoscope/Catheter Tips
,”
Proceedings of the Sixth International Symposium on Micro Machine and Human Science (MHS’95)
, pp.
83
88
.
7.
Tanimoto
,
M.
,
Arai
,
F.
,
Fukuda
,
T.
,
Iwata
,
H.
,
Itoigawa
,
K.
,
Gotoh
,
Y.
,
Hashimoto
,
M.
, and
Negoro
,
M.
, 1998, “
Micro Force Sensor for Intravascular Neurosurgery and In Vivo Experiment
,”
Proceedings of the IEEE International Workshop on Microelectromechanical Systems (MEMS’98)
, pp.
504
509
.
8.
Mineta
,
T.
,
Mitsui
,
T.
,
Watanabe
,
Y.
,
Kobayashi
,
S.
,
Haga
,
Y.
, and
Esashi
,
M.
, 2002, “
An Active Guide Wire With Shape Memory Alloy Bending Actuator Fabricated by Room Temperature Process
,”
Sens. Actuators, A
0924-4247,
97–98
, pp.
632
637
.
9.
Ohta
,
R.
, 2001, “
Results of R&D on Catheter-Type Micromachine
,”
Proceedings of the 2001 International Symposium on Micromechatronics and Human Science (MHS’01)
, pp.
5
12
.
10.
Ortmaier
,
T.
, 2002, “
Motion Compensation in Minimally Invasive Robotic Surgery
,” Ph.D. thesis, Technische Universität München, Munich, Germany.
11.
Cepolina
,
F.
, and
Michelini
,
R. C.
, 2004, “
Review of Robotic Fixtures for Low-Invasiveness Surgery
,”
Int. J. Med. Rob. Comput. Assist. Surg.
,
1
(
1
), pp.
43
63
.
12.
Wagner
,
C. R.
,
Stylopoulos
,
N.
, and
Howe
,
R. D.
, 2002, “
The Role of Force Feedback in Surgery: Analysis of Blunt Dissection
,”
Proceedings of the IEEE Tenth Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems
, pp.
73
79
.
13.
Eisinberg
,
A.
,
Izzo
,
I.
,
Valdastri
,
P.
,
Menciassi
,
A.
, and
Dario
,
P.
, 2004, “
A Teleoperated SDM-Based Microinstrument for Vessel Recognition During MIS
,”
Proceedings of the IEEE Mechatronics and Robotics (MechRob’04)
, Vol.
3
, pp.
1067
1071
.
14.
Kern
,
T. A.
, and
Werthschtzky
,
R.
, 2005, “
Design of a Haptic Display for Catheterization
,”
Proceedings of the IEEE First Joint Eurohaptics Conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems (WHC’05)
, pp.
477
478
.
15.
Seibold
,
U.
,
Kübler
,
B.
, and
Hirzinger
,
G.
, 2005, “
Prototype of Instrument for Minimally Invasive Surgery With 6-Axis Force Sensing Capability
,”
Proceedings of the IEEE International Conference on Robotic and Automation (ICRA’05)
, pp.
498
503
.
16.
Peirs
,
J.
,
Clijnen
,
J.
,
Reynaerts
,
D.
,
Brussel
,
H. V.
,
Herijgers
,
P.
,
Corteville
,
B.
, and
Boone
,
S.
, 2004, “
A Micro Optical Force Sensor for Force Feedback During Minimally Invasive Robotic Surgery
,”
Sens. Actuators, A
0924-4247,
115
, pp.
279
284
.
17.
Berkelman
,
P. J.
,
Whitcomb
,
L. L.
,
Taylor
,
R. H.
, and
Jensen
,
P.
, 2003, “
A Miniature Microsurgical Instrument Tip Force Sensor for Enhanced Force Feedback During Robot-Assisted Manipulation
,”
IEEE Trans. Rob. Autom.
1042-296X,
19
(
5
), pp.
917
922
.
18.
Chanthasopeephan
,
T.
,
Desai
,
J.
, and
Lau
,
A.
, 2003, “
Measuring Forces in Liver Cutting: New Equipment and Experimental Results
,”
Ann. Biomed. Eng.
0090-6964,
31
(
11
), pp.
1372
1382
.
19.
Chanthasopeephan
,
T.
,
Desai
,
J. P.
, and
Lau
,
A. C. W.
, 2004, “
Deformation Resistance in Soft Tissue Cutting: A Parametric Study
,”
Proceedings of the 12th International Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems (HAPTICS’04)
, pp.
323
330
.
20.
Bielser
,
D.
, and
Gross
,
M. H.
, 2000, “
Interactive Simulation of Surgical Cuts
,”
Proceedings of the Computer Graphics and Applications (CGA’00)
, pp.
116
442
.
21.
Beccai
,
L.
,
Roccella
,
S.
,
Arena
,
A.
,
Valvo
,
F.
,
Valdastri
,
P.
,
Menciassi
,
A.
,
Carrozza
,
M. C.
, and
Dario
,
P.
, 2005, “
Design and Fabrication of a Hybrid Silicon Three-Axial Force Sensor for Biomechanical Applications
,”
Sens. Actuators, A
0924-4247,
120
, pp.
370
382
.
22.
Valdastri
,
P.
,
Roccella
,
S.
,
Beccai
,
L.
,
Cattin
,
E.
,
Menciassi
,
A.
,
Carrozza
,
M. C.
, and
Dario
,
P.
, 2005, “
Characterization of a Novel Hybrid Silicon Three-Axial Force Sensor
,”
Sens. Actuators, A
0924-4247,
123–124C
, pp.
249
257
.
23.
Valdastri
,
P.
,
Harada
,
K.
,
Menciassi
,
A.
,
Beccai
,
L.
,
Stefanini
,
C.
,
Fujie
,
M.
, and
Dario
,
P.
, 2006, “
Integration of a Miniaturised Triaxial Force Sensor in a Minimally Invasive Surgical Tool
,”
IEEE Trans. Biomed. Eng.
0018-9294,
53
(
11
), pp.
2397
2400
.
24.
Basdogan
,
C.
,
De
,
S.
,
Kim
,
J.
,
Muniyandi
,
M.
,
Kim
,
H.
, and
Srinivasan
,
M. A.
, 2004, “
Haptics in Minimally Invasive Surgical Simulation and Training
,”
IEEE Comput. Graphics Appl.
0272-1716,
24
(
2
), pp.
56
64
.
25.
Ottensmeyer
,
M. P.
, and
Salisbury
,
J. K.
, 2001, “
In Vivo Data Acquisition Instrument for Solid Organ Mechanical Property Measurement
,”
Proceedings of the MICCAI
, pp.
975
982
.
You do not currently have access to this content.