Abstract
Paired thermoluminescence dosimeters and ionization chambers were used for characterizing mixed (neutron and photon) radiation fields at the LR-0, a zero power model of VVER reactors. Detector responses were investigated in standard photon and thermal neutron fields. A good agreement was obtained among the doses measured with the two methods. Furthermore, the measured photon and neutron attenuation values are consistent with those from evaluated, independent data.
Issue Section:
Research Papers
References
1.
Ošmera
, B.
and Zaritsky
, S.
, “WWER-1000 Mock-up Experiment
,” ÚJV č. 12036-R (Rev. 1), Nuclear Research Institute Řež plc (Czech Republic)
, 05
2002
.2.
Ošmera
, B.
,Cvachovec
, F.
, and Mařík
, M.
, “The Results of Photon Spectra Measurements Over the Reactor Pressure Vessel Simulator in WWER-100 Model in the LR-0 Experimental Reactor
,” REDOS-R(06), Issue 1, Nuclear Research Institute Řež plc
, 03
2004
.3.
Clinical Neutron Dosimetry Part 1: Determination of Absorbed Dose in a Patient Treated by External Beams of Fast Neutrons
, ICRU Report 45, International Commission on Radiation Units and Measurements
, Bethesda, MD, 1989
.4.
Raaijmakers
, C. P. J.
,Watkins
, P. R. D.
,Nottelman
, E. L.
, et al, “The Neutron Sensitivity of Dosimeters Applied to Boron Neutron Capture Therapy
,” Med. Phys.
0094-2405 https://doi.org/10.1118/1.597737, Vol. 23
, 1996
, pp. 1581
-1589
.5.
Kosunen
, A.
,Kortesniemi
, M.
,Ylä-Mella
, et al, “Twin Ionisation Chambers for Dose Determinations in Phantom in an Epithermal Neutron Beam
,” Radiat. Prot. Dosim.
0144-8420, Vol. 81
, No. 3
, 1999
, pp. 187
-194
.6.
Zoetlief
, J.
,Schlegel-Bickmann
, D.
,Schraube
, H.
, and Dietze
, G.
, “Characteristics of Mg/Ar Ionisation Chambers Used as Gamma-Ray Dosemeters in Mixed Neutron-Photon Fields
,” Phys. Med. Biol.
0031-9155, Vol. 3
, No. 12
, 1986
, pp. 1339
-1351
.7.
Waterman
, F. M.
,Kuchnir
, F. T.
, and Skaggs
, L. S.
, “Energy Dependence of the Neutron Sensitivity of C-CO2, Mg-Ar and TE-TE Ionisation Chambers
,” Phys. Med. Biol.
0031-9155 https://doi.org/10.1088/0031-9155/24/4/004, Vol. 24
, No. 4
, 1979
, pp. 721
-733
.8.
Absorbed Dose Determination in Photon and Electron Beams
, Technical Reports Series No. 277, International Atomic Energy Agency
, Vienna
, 1987
.9.
Horowitz
, Y. S.
, “Neutron Dosimetry
,” in Thermoluminescence and Thermoluminescent Dosimetry
Vol. II
, CRC Press
, Boca Raton, FL
, 1984
, pp. 90
-114
.10.
Hahn
, T.
,Fellinger
, J.
,Henniger
, J.
, et al, “Neutron Response of LiF TL Detectors
,” Radiat. Prot. Dosim.
0144-8420, Vol. 44
, No. 1–4
, 1992
, pp. 297
-300
.11.
Aït Abderrahim
, H.
,McGarry
, E. D.
, and Spiegel
, V.
, “Assessment of the Fast Neutron Sensitivity of Thermoluminescent Gamma Dosimeters
,” in Proc. 7th ASTM Symp. Reactor Dosimetry, Strasbourg, 1990
, Kluwer Academic Publishers
, Dordrecht
, 1992
, pp. 529
-536
.12.
Wang
, S. S.
,Cai
, G. G.
,Zhou
, K. Q.
, and Zhou
, R. X.
, “Thermoluminescence Response of 6LiF (Mg,Cu,P) and 6LiF (Mg,Cu,P) TL Chips in Neutron and Gamma Ray Mixed Fields
,” Radiat. Prot. Dosim.
0144-8420, Vol. 33
, No. 1–4
, 1990
, pp. 247
-250
.13.
Photon, Electron, Proton and Neutron Interaction Data for Body Tissues
, Report 46, International Commission on Radiation Units and Measurements
, Bethesda, MD, 1992
.14.
Serén
, T.
, “PC Programs for the Conversion of Neutron Spectra and Cross Sections Between Different Group and Point Representations
,” in Proc. 7th ASTM Symp. Reactor Dosimetry, Strasbourg, 1990
, Kluwer Academic Publishers
, Dordrecht
, 1992
, pp. 239
-246
.15.
Stallmann
, F. W.
, “LSL-M2: A Computer Program for Least-Squares Logarithmic Adjustment of Neutron Spectra
,” NUREG/CR-4349, ORNL/TM-9933, Oak Ridge National Laboratory
, 1986
.16.
Ošmera
, B.
,Kyncl
, J.
,Mařik
, M.
, et al, “The Gamma Ray Spectra Measurement in Reactor Pressure Vessel Simulator in WWER-1000 Engineering Benchmark
,” in Proc. 11th Intl. Symp. Reactor Dosimetry, Brussels, 2002
, World Scientific
, Singapore
, 2003
, pp. 512
-518
.
This content is only available via PDF.
All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of ASTM International.
You do not currently have access to this content.