Cold aisle containment is used in raised floor, air cooled data centers to minimize direct mixing between the supplied cold air and the hot air exiting from the servers. The objective of such a system is to minimize the server inlet air temperatures. In this paper, large scale air temperature field measurements are performed to investigate the hot air entrainment characteristics in the cold aisle in both open and contained aisle conditions. Both under-provisioned and over-provisioned scenarios were examined. Thermal field measurements suggest significant improvement in the cold air delivery for the case with contained aisle as compared to open aisle. Even for an over-provisioned case with open aisle, hot air entrainment was observed from the aisle entrance; however, for the contained aisle condition, close to perfect cold air delivery to the racks was observed. For both under-provisioned and over-provisioned cases, the aisle containment tended to equalize the tile and rack air flow rates. Balance air is expected to be leaked into or out of the containment to makeup the flow rate difference for the contained aisle condition. The CFD modeling strategy at the aisle level is also discussed for open aisle condition. Our previous investigation for rack level modeling has shown that consideration of momentum rise above the tile surface improves the predictive capability as compared to the generally used porous jump model. The porous jump model only specifies a step pressure loss at the tile surface without any influence on flow field. The momentum rise above the tile surface was included using a modified body force model by artificially specifying a momentum source above the tile surface. The modified body force model suggested higher air entrainment and higher reach of cold air as compared to the porous jump model. The modified body force model was able to better capture hot air entrainment through aisle entrance and compared well with the experimental data for the end racks. The generally used porous jump model suggested lower hot air entrainment and under predicted the server inlet temperatures for end racks.
Skip Nav Destination
Atlanta, GA 30332
Milford, NH 03055
Article navigation
Research-Article
Thermal Characteristics of Open and Contained Data Center Cold Aisle
Vaibhav K. Arghode,
Vaibhav K. Arghode
1
e-mail: vaibhav.arghode@me.gatech.edu
1Corresponding author.
Search for other works by this author on:
Yogendra Joshi,
Atlanta, GA 30332
Yogendra Joshi
George W. Woodruff School of Mechanical Engineering
,Georgia Institute of Technology
,Atlanta, GA 30332
Search for other works by this author on:
Wally Phelps
Milford, NH 03055
Wally Phelps
Degree Controls Inc.
,Milford, NH 03055
Search for other works by this author on:
Vaibhav K. Arghode
e-mail: vaibhav.arghode@me.gatech.edu
Yogendra Joshi
George W. Woodruff School of Mechanical Engineering
,Georgia Institute of Technology
,Atlanta, GA 30332
Wally Phelps
Degree Controls Inc.
,Milford, NH 03055
1Corresponding author.
Manuscript received November 20, 2012; final manuscript received January 23, 2013; published online May 16, 2013. Assoc. Editor: Leslie Phinney.
J. Heat Transfer. Jun 2013, 135(6): 061901 (11 pages)
Published Online: May 16, 2013
Article history
Received:
November 20, 2012
Revision Received:
January 23, 2013
Citation
Arghode, V. K., Sundaralingam, V., Joshi, Y., and Phelps, W. (May 16, 2013). "Thermal Characteristics of Open and Contained Data Center Cold Aisle." ASME. J. Heat Transfer. June 2013; 135(6): 061901. https://doi.org/10.1115/1.4023597
Download citation file:
Get Email Alerts
Cited By
Related Articles
Room Level Modeling of Air Flow in a Contained Data Center Aisle
J. Electron. Packag (March,2014)
Experimental Characterization of Various Cold Aisle Containment Configurations for Data Centers
J. Electron. Packag (March,2015)
Rack Level Modeling of Air Flow Through Perforated Tile in a Data Center
J. Electron. Packag (September,2013)
Experimental and Numerical Analysis of Data Center Pressure and Flow Fields Induced by Backward and Forward CRAH Technology
J. Electron. Packag (September,2022)
Related Proceedings Papers
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Insights and Results of the Shutdown PSA for a German SWR 69 Type Reactor (PSAM-0028)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)