An experimental investigation of the thermal contact conductance of anodized coatings, synthesized at different bath temperatures and in different electrolyte solutions, was performed, and the results were compared with previously published information. Electrolyte solutions of sulfuric acid at bath temperature of 7°C (Type III) and 25°C (Type II) and chromic acid at a bath temperature of 54°C (Type I) were used to grow coating thicknesses ranging from 3.2 to 61 μm (0.11 to 2.4 mil). Experimental thermal contact conductance data were obtained for a junction between anodized aluminum 6101-T6 and uncoated aluminum A356-T61 as a function of apparent contact pressure and anodized coating thickness. Apparent contact pressure ranged from 172 to 2760 kPa (25 to 400 psi) and the mean interface temperature was maintained at 40°C (104°F). The thermal contact conductance for the low-temperature sulfuric acid anodized (Type III) coatings varied from 300 to 13,000 W/m2 K, while the conductance of the room temperature sulfuric anodized (Type II) coatings varied between 100 to 3000 W/m2 K. The chromic acid (Type I) coatings yielded conductance values of 60 to 3000 W/m2 K. In general, the use of elevated temperatures for the anodizing bath will lead to lower surface microhardness and lower thermal contact conductance. The greatest conductance measurements were obtained for coatings grown in low-temperature sulfuric acid.
Skip Nav Destination
Article navigation
Research Papers
The Thermal Contact Conductance of Hard and Soft Coat Anodized Aluminum
M. A. Lambert,
M. A. Lambert
Mechanical Engineering Department, Texas A&M University, College Station, TX 77843-3123
Search for other works by this author on:
E. E. Marotta,
E. E. Marotta
Mechanical Engineering Department, Texas A&M University, College Station, TX 77843-3123
Search for other works by this author on:
L. S. Fletcher
L. S. Fletcher
Mechanical Engineering Department, Texas A&M University, College Station, TX 77843-3123
Search for other works by this author on:
M. A. Lambert
Mechanical Engineering Department, Texas A&M University, College Station, TX 77843-3123
E. E. Marotta
Mechanical Engineering Department, Texas A&M University, College Station, TX 77843-3123
L. S. Fletcher
Mechanical Engineering Department, Texas A&M University, College Station, TX 77843-3123
J. Heat Transfer. May 1995, 117(2): 270-275 (6 pages)
Published Online: May 1, 1995
Article history
Received:
November 1, 1993
Revised:
May 1, 1994
Online:
December 5, 2007
Citation
Lambert, M. A., Marotta, E. E., and Fletcher, L. S. (May 1, 1995). "The Thermal Contact Conductance of Hard and Soft Coat Anodized Aluminum." ASME. J. Heat Transfer. May 1995; 117(2): 270–275. https://doi.org/10.1115/1.2822516
Download citation file:
Get Email Alerts
Cited By
Related Articles
The Interfacial Pressure Distribution and Thermal Conductance of Bolted Joints
J. Heat Transfer (November,1994)
Measurement of the Thermal Contact Conductance and Thermal Conductivity of Anodized Aluminum Coatings
J. Heat Transfer (August,1990)
Thermal Gap Conductance of Conforming Surfaces in Contact
J. Heat Transfer (August,1993)
Evaluation of Thermal Contact Conductance Between Mold Compound and Heat Spreader Materials
J. Heat Transfer (November,1988)
Related Proceedings Papers
Related Chapters
Radiation
Thermal Management of Microelectronic Equipment
Radiation
Thermal Management of Microelectronic Equipment, Second Edition
Thermal Design Guide of Liquid Cooled Systems
Thermal Design of Liquid Cooled Microelectronic Equipment