With the introduction of high-speed cutting tools, clinicians have recognized the potential for thermal damage to the material being cut. Here, we developed a mathematical model of heat transfer caused by drilling bones of different densities and validated it with respect to experimentally measured temperatures in bone. We then coupled these computational results with a biological assessment of cell death following osteotomy site preparation. Parameters under clinical control, e.g., drill diameter, rotational speed, and irrigation, along with patient-specific variables such as bone density were evaluated in order to understand their contributions to thermal damage. Predictions from our models provide insights into temperatures and thresholds that cause osteocyte death and that can ultimately compromise stability of an implant.

References

1.
Mediouni
,
M.
,
Schlatterer
,
D. R.
,
Khoury
,
A.
,
Von Bergen
,
T.
,
Shetty
,
S. H.
,
Arora
,
M.
,
Dhond
,
A.
,
Vaughan
,
N.
, and
Volosnikov
,
A.
,
2017
, “
Optimal Parameters to Avoid Thermal Necrosis During Bone Drilling: A Finite Element Analysis
,”
J. Orthop. Res.
,
35
(
11
), pp.
2386
2391
.
2.
Toyne
,
J. M.
,
2015
, “
Tibial Surgery in Ancient Peru
,”
Int. J. Paleopathol.
,
8
, pp.
29
35
.
3.
Thompson
,
H. C.
,
1958
, “
Effect of Drilling Into Bone
,”
J. Oral Surg. (Chic)
,
16
(
1
), pp.
22
30
.
4.
Pallan
,
F. G.
,
1960
, “
Histological Changes in Bone after Insertdon of Skeletal Fixation Pins
,”
J. Oral Surg., Anesth. Hosp. Dent. Serv.
,
18
, pp.
400
408
.
5.
Matthews
,
L. S.
, and
Hirsch
,
C.
,
1972
, “
Temperatures Measured in Human Cortical Bone When Drilling
,”
J. Bone Jt. Surg. Am.
,
54
(
2
), pp.
297
308
.
6.
Abouzgia
,
M. B.
, and
James
,
D. F.
,
1997
, “
Temperature Rise During Drilling Through Bone
,”
Int. J. Oral Maxillofac. Implants
,
12
(
3
), pp.
342
353
.
7.
Augustin
,
G.
,
Davila
,
S.
,
Mihoci
,
K.
,
Udiljak
,
T.
,
Vedrina
,
D. S.
, and
Antabak
,
A.
,
2008
, “
Thermal Osteonecrosis and Bone Drilling Parameters Revisited
,”
Arch. Orthop. Trauma Surg.
,
128
(
1
), pp.
71
77
.
8.
Abayazid
,
A.
,
2010
,
Modeling Heat Generation and Temperature Distribution During Dental Surgical Drilling
,
Delft University of Technology
,
Delft, Netherlands
.
9.
Zhou
,
S.
,
Yang
,
Y.
,
Ha
,
N.
,
Zhang
,
P.
,
Ma
,
X.
,
Gong
,
X.
,
Hong
,
Y.
,
Yang
,
X.
,
Yang
,
S.
,
Dai
,
Q.
, and
Jiang
,
L.
,
2018
, “
The Specific Morphological Features of Alveolar Bone
,”
J. Craniofac. Surg.
, epub.
10.
Davidson
,
S. R.
, and
James
,
D. F.
,
2003
, “
Drilling in Bone: Modeling Heat Generation and Temperature Distribution
,”
ASME J. Biomech. Eng.
,
125
(
3
), pp.
305
314
.
11.
Davidson
,
S. R. H.
, and
James
,
D. F.
,
2000
, “
Measurement of Thermal Conductivity of Bovine Cortical Bone
,”
Medical Eng. Phys.
,
22
(
10
), pp.
741
747
.
12.
Kuster
,
N.
, and
Capstick
,
M.
,
2017
, “
The Foundation for Research on Information Technologies in Society
,” IT'IS Foundation, Zurich, Switzerland, accessed May 26, 2018, https://www.itis.ethz.ch/news-events/news/latest-news/
13.
Incropera
,
F. P.
, Dewitt, D. P., Bergman, T. L., and Lavine, A. S.,
2007
,
Fundamentals of Heat and Mass Transfer
,
Wiley
,
Hoboken, NJ
.
14.
Lee
,
J.
,
Rabin
,
Y.
, and
Ozdoganlar
,
O. B.
,
2011
, “
A New Thermal Model for Bone Drilling With Applications to Orthopaedic Surgery
,”
Med. Eng. Phys.
,
33
(
10
), pp.
1234
1244
.
15.
Tu
,
Y. K.
,
Chen
,
L. W.
,
Ciou
,
J. S.
,
Hsiao
,
C. K.
, and
Chen
,
Y. C.
,
2013
, “
Finite Element Simulations of Bone Temperature Rise During Bone Drilling Based on a Bone Analog
,”
J. Med. Biol. Eng.
,
33
(
3
), pp.
269
274
.
16.
Eriksson
,
A. R.
, and
Albrektsson
,
T.
,
1983
, “
Temperature Threshold Levels for Heat-Induced Bone Tissue-Injury—A Vital-Microscopic Study in the Rabbit
,”
J. Prosthet. Dent.
,
50
(
1
), pp.
101
107
.
17.
Gonzalez-Garcia
,
R.
, and
Monje
,
F.
,
2013
, “
Is Micro-Computed Tomography Reliable to Determine the Microstructure of the Maxillary Alveolar Bone?
,”
Clin. Oral Implants Res.
,
24
(
7
), pp.
730
737
.
18.
Nobel Biocare,
2014
, “
Nobel Active Procedures Manual
,” Nobel Biocare, Zurich, Switzerland, accessed May 26, 2018, https://www.artisbiotech.ro/wp-content/uploads/Manual-Nobel-Active.pdf
19.
Thakur
,
A. J.
,
1997
,
The Elements of Fracture Fixation
,
Churchill
Livingston, New York
.
20.
Branemark
,
P. I.
,
Zarb
,
G.
, and
Albrektsson
,
T.
,
1985
,
Tissue Integrated Prostheses
,
Quintessence Publishing
,
Chicago, IL
.
21.
Flanagan
,
D.
,
2010
, “
Osteotomy Irrigation: Is It Necessary?
,”
Implant Dent.
,
19
(
3
), pp.
241
249
.
22.
Cranin
,
A. N.
,
Klein
,
M.
, and
Simons
,
A.
,
1999
,
Atlas of Oral Implantology
,
Mosby
,
St. Louis, MO
.
23.
Li
,
J.
,
Yin
,
X.
,
Huang
,
L.
,
Mouraret
,
S.
,
Brunski
,
J. B.
,
Cordova
,
L.
,
Salmon
,
B.
, and
Helms
,
J. A.
,
2017
, “
Relationships Among Bone Quality, Implant Osseointegration, and Wnt Signaling
,”
J. Dent. Res.
,
96
(
7
), pp.
822
831
.
You do not currently have access to this content.