Blood flow-through segments of large arteries of man, between adjacent bifurcations, can be modeled as pulsatile flow in tapered converging tubes, of small angle of convergence, up to 2 deg. Assuming linearity, rigid tube and homogeneous Newtonian fluid, the physiological flow field is governed by the Navier-Stokes equation with dominant nonlinear and unsteady terms. Analytical solution of this problem is presented based on an integral method technique. The solution shows that even for small tapering the flow pattern is markedly different from the flow obtained for a uniform tube. The periodic shear stresses at the wall and pressure gradients increase both in their mean value and amplitude with increased distance downstream. These results are highly significant in the process of atherogenesis.
Skip Nav Destination
Article navigation
Research Papers
Pulsatile Flow in Tapered Tubes: A Model of Blood Flow With Large Disturbances
E. Kimmel,
E. Kimmel
Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, Israel
Search for other works by this author on:
U. Dinnar
U. Dinnar
Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, Israel
Search for other works by this author on:
E. Kimmel
Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, Israel
U. Dinnar
Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, Israel
J Biomech Eng. May 1983, 105(2): 112-119 (8 pages)
Published Online: May 1, 1983
Article history
Received:
January 23, 1982
Revised:
October 18, 1982
Online:
June 15, 2009
Citation
Kimmel, E., and Dinnar, U. (May 1, 1983). "Pulsatile Flow in Tapered Tubes: A Model of Blood Flow With Large Disturbances." ASME. J Biomech Eng. May 1983; 105(2): 112–119. https://doi.org/10.1115/1.3138394
Download citation file:
Get Email Alerts
Cited By
A Feasible Low-Cost System for Kinematic and Kinetic Analysis of Sit-to-Stand Movement
J Biomech Eng (April 2025)
Related Articles
Computational Modeling of LDL and Albumin Transport in an In Vivo CT Image-Based Human Right Coronary Artery
J Biomech Eng (February,2009)
Numerical Simulation of Local Blood Flow in the Carotid and Cerebral Arteries Under Altered Gravity
J Biomech Eng (April,2006)
Influence of Non-Newtonian Behavior of Blood on Flow in an Elastic Artery Model
J Biomech Eng (February,1996)
Related Proceedings Papers
Related Chapters
Two Advanced Methods
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Hemolysis
Mechanical Blood Trauma in Circulatory-Assist Devices